SmartOnline 30kVA/24kW 230/400V 3-Phase UPS System Hardwire Input/Output - SU30K3/3INT
- Provides 30000VA, 24000watt(s), 230V, 400V power / Surge Suppression is Standard
- Connector(s): Hardwired / 1 Outlets
- 5 minute(s) Battery Runtime at Full Load / Attributes include Double conversion online
Tripp Lite's SU30K3/3X SmartOnline 3-Phase Intelligent, True On-Line UPS System provides mission-critical equipment with the highest level of power protection available. Its large capacity 30,000 VA/24,000 watt power module continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with a pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time offers compatibility with all equipment types. SmartOnline models provide some of the highest levels of isolation from THD (total harmonic distortion) <3% allowing equipment to perform at its peak. A 3:1 crest factor safely supports a variety of equipment, even those with wildly-fluctuating power demands. Extremely efficient operation (up to 97% efficient in Economy Mode) saves money by lowering electricity consumption.
Hardwire input and output connections support a variety of permanent or PDU style power connections. The SU30K3/3X features user-selectable 3-phase 220/380 or 230/400 or 240/415VAC input and output with a wide input voltage correction range (176-288/304-499VAC). Frequency is 50 or 60Hz (auto-selectable). The SU30K3/3X includes a power module and an external battery module, both in tower format cabinets. Battery support can be extended with optional external battery modules. A manual bypass switch as well as an automatic bypass function ensure 100% availability of connected equipment by safely passing through AC power when the power module requires maintenance.
Three built-in communication ports (RS-232, contact closure and AS-400) work with the included PowerAlert Software to simultaneously provide shutdown commands and reporting on multiple servers without the need for costly accessories. An accessory slot accepts an optional internal SNMP card (model # SNMPWEBCARD) for remote shutdowns, reboots and more. A Battery Start Switch allows cold restart of UPS during a prolonged blackout to utilize its batteries for periodic system access or data retrieval. An Emergency Power Off button turns UPS output OFF and disables Bypass output. Built-in Emergency Power Off (EPO) interface supports remote emergency shutdown in large facilities. Front panel combination LCD/LED display alerts users to a variety of UPS operational modes and conditions.
SmartOnline 30kVA/24kW 230/400V 3-Phase UPS System Hardwire Input/Output - SU30K3/3INT
|
Connectivity
|
|
|
Connector
|
Hardwired
|
|
# Ports
|
1
|
|
Communication Interface
|
Contact closure
|
|
Communication Interface
|
Serial (RS-232)
|
|
General
|
|
|
Form Factor
|
Tower
|
|
Attributes
|
Double conversion online
|
|
Power
|
|
|
Power Provided
|
400 V
|
|
Power Provided
|
30000 VA
|
|
Power Provided
|
24000 watt(s)
|
|
Battery Run Time (max)
|
5 minute(s)
|
|
Power Provided
|
230 V
|
|
Surge Suppression
|
Standard
|
|
Actual Weight
|
627.00 lb(s)
|
|
Compatibility Notes
|
LEDS ALARMS & SWITCHES
Front panel: (7) LED DISPLAY - AC input, bypass input, AC-DC charger, DC-AC inverter, AC output, bypass operation and battery operation. SELECTABLE LCD DISPLAY - indicates a wide range of UPS operational and fault / warning conditions including operational mode, alarm / shutdown conditions, input / output voltage / frequency, battery voltage, load percentage and more. Alarms: warnings against a variety of operational conditions: low battery, overload, shutdown, bypass and more Switches "ON" button turns UPS's inverter ON. "OFF" button turns UPS's inverter OFF. "Select" Button browses through items displayed on LCD screen. "Enter" button selects items displayed on LCD screen. "Select" and "Enter" buttons used simultaneously mute UPS alarms. "Battery Start" Switch cold starts the inverter. "Emergency Power Off" button turns UPS output OFF and disables Bypass output. "Manual Bypass" switch bypasses the UPS's inverter during maintenance.
SURGE / NOISE SUPPRESSION
AC suppression response time: Instantaneous EMI / RFI AC noise suppression: Yes
COMMUNICATIONS
Network monitoring port: (3) built-in communications ports (RS-232, contact closure and AS-400) Software and cabling: PowerAlert UPS monitoring software for all common network and standalone operating systems. Cabling included. SNMP compatibility: Built-in accessory slot accommodates internal SNMP card (model # SNMPWEBCARD, available separately) and other network accessories
LINE / BATTERY TRANSFER
Transfer time from line power to battery mode: Zero transfer time. True on-line UPS continuously converts incoming AC to DC, then back to AC. When line power is interrupted, UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power. Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 156 / 270VAC (Y, 3-Phase, 4 Wire). Below this point, output is maintained utilizing battery reserves. High voltage transfer to battery power Maintains continuous operation during overvoltages as high as 280 / 485VAC (Y, 3-Phase, 4 Wire). Above this point, output is maintained utilizing battery reserves.
|
|
Contents
|
UPS, software with cabling, documentation
|
|
Physical Dimensions
|
54"h x 18"w x 36"d
|
|
Power Notes
|
Voltage compatibility 220 / 380, 230 / 400 or 240 / 415V AC, 3-phase, 4-wire (plus ground), wye Frequency compatibility 50 / 60 Hz (auto-selectable)
OUTPUT Output: 30kVA / 24kW Output nominal voltage: 220 / 380, 230 / 400 or 240 / 415VAC, 3-phase, 4-wire (plus ground), wye Output voltage regulation: Maintains pure sine wave output at all times, regulated within 2% of selected nominal output voltage, less than 3% total harmonic distortion Output frequency regulation: Regulates line frequency at 50 or 60Hz, + / - 3Hz
INPUT
Maximum input current: 45A Recommended electrical service 220 / 380 or 230 / 400 or 240 / 415VAC
BATTERY
Full load runtime: Included internal batteries - 5 minutes (24, 000 watts). Runtime can be extended with additional SURBC2030 internal battery modules (available separately). Half load runtime: Included internal batteries - 13 minutes (12, 000 watts) Expandable battery runtime Supports extended runtime with optional internal battery modules. Accepts (2) additional SURBC2030 internal battery modules along with additional external battery frames (model # SUBF2030, available separately) DC system voltage: 240VDC Typical battery lifespan: 3-6 years, depending on usage Battery recharge rate: 2-4 hours to 90%
VOLTAGE REGULATION
Voltage regulation description: On-line, double-conversion process gives this UPS the ability to maintain output voltage within + / -2% of selected nominal voltage at all times Overvoltage correction: Maintains continuous operation without using battery power during overvoltages to 280 / 485VAC (Y, 3-Phase, 4 Wire), reducing output within 2% of selected nominal Brownout correction: Maintains continuous operation without using battery power during brownout / undervoltage conditions to 156 / 270VAC (Y, 3-Phase, 4 Wire)
|
|
Returns Policy
|
This product is subject to our return policy. Please see our complete return policy for details.
|
|
Warranty - Labor
|
2 Years
|
|
Warranty - Parts
|
2 Years
|
|
Warranty Details
|
2 years on power module, 1 year on batteries
|
SmartOnline 30kVA/24kW 230/400V 3-Phase UPS System Hardwire Input/Output - SU30K3/3INT