HP R12000/3 12kVA/12kW 208V 3-Phase 6U Rackmount UPS (2) NEMA L15-30R Outlets - AF429A
- Provides 12000VA power / Surge Suppression is Standard
- 2 Outlets
- 5 minute(s) Battery Runtime at Full Load / Attributes include Double conversion online, Line interactive
The HP 3-Phase Uninterruptible Power System provides unity-rated uninterruptible power with increased power density and power efficiency. This rack-mountable Uninterruptible Power System provides up to 12,000 watts (W) of power in a 6U rack form factor. This equates to 2kW per U space, which leads the industry in power density. The UPS R12000/3 uses digital signal processing and a new On-line On Demand hybrid technology to answer the demands for increased power density and power efficiency.
On-line On Demand combines the efficiency of a line interactive UPS, up to 97%, with the stability of a double conversion on-line UPS when power fluctuates beyond acceptable limits. Hot swappable batteries and electronics modules and an automatic bypass reduce MTTR (mean time to repair) – down time in the event service is needed.
The HP 3-Phase UPS incorporates Enhanced Battery Management, which is an exclusive, patented technology that doubles battery service life, optimizes battery recharge time, and provides advance notice of pending battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and receive the best in the industry protection for your critical equipment.
The HP 3-Phase UPS has a modular design architecture, consisting of separate, hot swappable battery and electronics modules. Further, a built-in intelligent automatic bypass feature ensures continuous power to your connected load even while the modules are being replaced.
The HP 3-Phase UPS supports a maximum of four Extended Runtime Modules (ERM, available separately), to further increase your battery back-up time, should you have a sudden brief power outage. Each ERM is 3U high and can be automatically detected and configured when attached to the UPS.
The HP 3[Phase UPS includes an isolated REPO (Remote Emergency Power Off) port. The REPO feature allows the power to the UPS outlets to be switched off from a remote location.
The HP 3-Phase UPS systems can be fully configured and monitored from the front management LCD. For remote management the HP UPS Management Module is included at no charge and provides additional features such as out of band communications with up to (5) servers and UPS clustering for redundancy.
HP R12000/3 12kVA/12kW 208V 3-Phase 6U Rackmount UPS (2) NEMA L15-30R Outlets - AF429A
|
Connectivity
|
|
|
Communication Interface
|
Serial (RS-232)
|
|
# Ports
|
2
|
|
General
|
|
|
Form Factor
|
6U Rackmount
|
|
Attributes
|
Double conversion online
|
|
Attributes
|
Line interactive
|
|
Power
|
|
|
Battery Run Time (max)
|
5 minute(s)
|
|
Power Provided
|
12000 VA
|
|
Surge Suppression
|
Standard
|
|
Actual Weight
|
307.00 lb(s)
|
|
Compatibility Notes
|
Unit Weight
Without batteries: 135 lbs. (61kg) With batteries installed: 307 lbs. (140kg)
|
|
Contents
|
UPS, documentation
|
|
Physical Dimensions
|
10.3"h x 14.4"w x 26"d
|
|
Ports/Connectors
|
(2) NEMA L15-30R outlets (1) IEC309 560P9 (60A) input connection
|
|
Power Notes
|
Electrical Output
Power Output: 12kVA / 12kW @ 208VAC 3-phase delta Nominal output frequency: 50-60Hz auto-detection (Normal mode), 50 or 60Hz (Battery mode) Output Frequency Variation: Synchronized (Normal mode), + / - 0.1 when not synchronized with source (Battery mode) Output overload: 100–110% load transfers to Bypass mode after 10 minutes; 110–125% load transfers to Bypass mode after 1 minute; 125–150% load transfers to Bypass mode after 5 seconds; >150% load transfers to Bypass mode after 300ms Voltage wave form: Sine wave, 2% THD with typical PFC load Surge suppression: High-energy 6500A peak Noise filtering: MOVs and line filter
Electrical Input
Voltage Range: 208VAC 3-phase Wye Nominal voltage: 208VAC 3-phase Wye Nominal frequency: 50 / 60Hz Frequency range: 45-65Hz Efficiency: 97% @ 40-100% load
Battery Runtime (with Internal Battery)
Estimated Backup Time, half load: 13 minutes (6000W) Estimated Backup Time, full load: 5 minutes (12000W)
|
|
Returns Policy
|
This product is subject to our return policy. Please see our complete return policy for details.
|
|
Warranty - Labor
|
1 Year
|
|
Warranty - Parts
|
3 Years
|
|
Warranty Details
|
$250, 000 equipment protection guarantee
|
HP R12000/3 12kVA/12kW 208V 3-Phase 6U Rackmount UPS (2) NEMA L15-30R Outlets - AF429A
http://www.pcconnection.com/IPA/Shop/Product/Detail.htm?sku=8374605#BVSecondaryCustomerRatings